Las cookies nos ayudan en la prestación de nuestros servicios. Mediante el uso de nuestros servicios declara estar de acuerdo sobre la utilización de cookies por nuestra parte. Conocer más.

Preguntas frecuentes

Which are the advantages of the digital Master-Slave function?

With these models the switching threshold can be set up automatically via the push of a button. If you don’t require the master-slave function at the moment, you can activate the permanent mode for the slave sockets if desired. The power strip will then ignore the master-slave function. The stored switching threshold, or rather the permanent mode, will also remain if the master-slave power strip is temporarily turned off by the main switch.

¿Por qué mi regleta de enchufes ya no desconecta enchufes secundarios?

En algunos casos sucede que los enchufes secundarios no se desconectan aun cuando el dispositivo principal se encuentra apagado. Esto puede deberse a corrientes de entrada muy altas de los dispositivos secundarios conectados, provocando un exceso en la capacidad máxima del relé y dando lugar a una soldadura de los contactos de conmutación.
En muchos casos, los contactos de conmutación pueden volver a separarse mediante vibraciones (golpeteo) y así permitir de nuevo su funcionamiento normal. Sin embargo, por lo general, el problema suele producirse de nuevo sin un cambio en la configuración de los dispositivos secundarios con suma rapidez.  

Consideraciones:

El conjunto de nuestras regletas de enchufes automáticas y los relés utilizados están diseñados para unas corrientes de carga continua de 16A. Los terminales no deben consumir más potencia con una toma de corriente tipo schuko. Sin embargo, algunos terminales superan considerablemente este límite al encenderse. El consumo de corriente puede alcanzar o incluso superar durante una fracción de segundo, por ejemplo los 50A o más. Estas corrientes elevadas pueden causar una soladura en el relé de los contactos de conmutación, de manera que el relé ya no se podrá desconectar.
Por experiencia se ha demostrado que el problema es más habitual en los terminales con fuentes de alimentación conmutadas. Aunque hoy en día dichos elementos pueden estar instalados en casi cualquier aparato, por ejemplo, PC, monitor, impresora, discos duros externos, altavoces... Saber qué productos pueden presentar este tipo de problemas depende también de si el fabricante de los dispositivos ha tomado las medidas adecuadas contra las entradas excesivas de corrientes. Desafortunadamente es algo que no se puede identificar ni en la hoja de datos ni en la placa de identificación. En nuestro caso hemos decidido por optimizar nuestras regletas de enchufe automáticas mediante la implementación de relés especiales para cargas en régimen de impulsos de hasta 80A. De esta manera el problema aparece con mucha menor frecuencia.

What can I use an automatic Master-Slave power strip for?

The power switch of a single device plugged into the master socket will automatically shut on and off all other devices plugged into the slave sockets. For example, you can use a computer as a master device, and a printer, monitor, modem and so on as slave devices incorporated into the automatic control. Of course you can also use such combinations as TV, radio, receiver, and so on.

How do I set up the switching threshold at an automatic power strip with control?

1. Place your master device in the master socket and switch it on. 2. Slowly and carefully turn the control of the switching threshold until you find a position in which the slave socket will be turned on and off. Note this as control position 1. (for users with higher power consumption leave the slave socket on). 3. Turn the master device off again, but let it remain plugged in. 4. Slowly and carefully turn the control of the switch until you find a position in which the slave socket will be truned on and off. Note this as control position 2. (for users with or without lower standby-power consumption the slave sockets stay turned on at all times). 5. Adjust the control in the centre between control position 1 and control position 2. (if you cannot find control position one or two adjust the control in the centre between the controller stops).

How do I set up the switching threshold at an automatic power strip with control?

How do I set up the switching threshold on an automatic power strip with a digital master-slave function?

These devices feature an automatic switching threshold setting, which is activated by pressing a button: 1. Turn on the automatic power strip at the main switch. 2. Insert the master device into the master socket. 3. Switch the master device into the standby mode or turn it off completely, if it is not already. 4. Press and hold the button Learn” on the automatic power strip for approx. 3 sec., until the “Slave on” lamp begins to blink. 5. The lamp “Slave on blinks only for a short time. During this time the standby power consumption of the master device will automatically ascertain and store the switching threshold. 6. If the lamp “Slave on” stops blinking, the setup procedure is finished. The automatic switch function can now be used.

How do I set up the switching threshold on an automatic power strip with a digital master-slave function?

Permanent mode with an automatic power strip with digital master-slave function.

To activate permanent mode: • Proceed as with the automatic switching threshold adjustment. • While the “slave on” light is blinking (step 5), press the button “learn” again for 3 sec. The automatic switching threshold adjustment will be finished and the permanent mode for the slave socket will be activated. To deactivate permanent mode: • Perform the automatic switching threshold adjustment again.